TOP
月月讀書金,登入即領,滿600現折50!!
Hvac Chilled Water Distribution Schemes ― Quick Book
滿額折

Hvac Chilled Water Distribution Schemes ― Quick Book

商品資訊

定價
:NT$ 2319 元
無庫存,下單後進貨(到貨天數約30-45天)
下單可得紅利積點 :69 點
商品簡介

商品簡介

In large commercial and industrial systems, chilled water system serves as means to transfer heat from building spaces to the refrigeration system. Initially, when energy costs were low, constant volume and primary-secondary systems provided a stable and simple operation of the chillers and distribution systems. However, as energy costs increased, particularly in the late 1970s, the efficiency of the chillers and the costs associated with operating the distribution system became more important. As a result, the need for new schemes to improve chiller performance and reduce energy costs drove the HVAC industry to advance chilled water technology, particularly in the manner that chilled water is delivered. To understand the hydraulic considerations associated with delivering chilled water and how they influence system performance, it is important to understand how technology and design challenges over the years have influenced today’s approach to chilled water pumping. This 5 - hour Quick Book discusses the history of chilled water distribution systems and the development of “variable primary flow system”. Problems such as low delta-T syndrome associated with the chilled water pumping schemes are defined and discussed and finally, this course compares the advantages and disadvantages of primary-secondary and direct-primary pumping schemes. Three chilled water schemes are discussed:SCHEME -1: CONSTANT FLOW CHILLED WATER SYSTEM SCHEME -2: PRIMARY / SECONDAY DISTRIBUTION SCHEMESCHEME -3: VARIABLE PRIMARY FLOW SCHEMEThe course includes a multiple-choice quiz consisting of twenty five (25) questions at the end to enhance course learning. Learning ObjectiveAt the conclusion of this course, the student will able to understand:1. The basic hydronic principles i.e. relationship of chilled water flow rate v/s cooling load and the energy savings due to adjustable speed pumps. 2. How do constant volume chilled water systems different from primary/secondary arrangement?3. What is low delta-T syndrome and how it affects the chiller loading?4. What are the causes and mitigation measures to prevent low delta-T syndrome?5. Why distributed pumping arrangement is better than headered arrangement for constant flow systems?6. How do primary/secondary chilled water systems create hydraulically independent loops?7. How to size the de-coupler bridge?8. The characteristics of control valves and why 2-way valve is better than 3-way valve in variable flow systems?9. How do the variable primary flow system compare with primary/secondary system in terms of cost and energy?10. The importance of design tube velocity and rate of chilled water flow variations in variable primary flow systems.

購物須知

外文書商品之書封,為出版社提供之樣本。實際出貨商品,以出版社所提供之現有版本為主。部份書籍,因出版社供應狀況特殊,匯率將依實際狀況做調整。

無庫存之商品,在您完成訂單程序之後,將以空運的方式為你下單調貨。為了縮短等待的時間,建議您將外文書與其他商品分開下單,以獲得最快的取貨速度,平均調貨時間為1~2個月。

為了保護您的權益,「三民網路書店」提供會員七日商品鑑賞期(收到商品為起始日)。

若要辦理退貨,請在商品鑑賞期內寄回,且商品必須是全新狀態與完整包裝(商品、附件、發票、隨貨贈品等)否則恕不接受退貨。

定價:100 2319
無庫存,下單後進貨
(到貨天數約30-45天)

暢銷榜

客服中心

收藏

會員專區